I have two Hoymiles HMS-1600-4T and HMS-2000-4T inverters, set to CEI 0-21 (Italy) using the official Hoymiles DTU. OpenDTU shows the profile as "Unknown".

This patch, written with the help of Claude:

Raw profile from /api/gridprofile/rawdata:

[8,0,32,0,0,11,8,252,7,163,0,15,9,226,0,30,1,89,0,20,10,85,0,20,9,226,16,3,19,136,19,116,0,1,19,156,0,1,18,142,0,10,20,30,0,10,32,0,0,1,48,3,11,184,9,226,7,163,19,146,19,126,64,0,0,33,0,33,80,1,0,1,19,156,3,1,0,33,0,0,96,0,0,1,9,226,9,236,39,16,128,1,0,0,8,22,1,44,8,68,9,180,9,226,1,44,0,30,144,0,0,1,0,100,176,1,0,0,1,244,0,95,9,111,8,252,112,0,0,1,160,2,0,0,0,0,68,34]

Add profile type 0x08 0x00 (IT_CEI0-21) and the Watt Power Factor
section version 0x01, which carries two additional voltage values
(lock-in / lock-out voltage of the cos phi(P) curve).

Also fix getSectionStart() returning the last table index instead of
-1 for unknown section versions, which produced an empty section
followed by garbage values.