feat(hoymiles): early RX exit for faster inverter control - #3225

Merged
tbnobody merged 1 commit into
tbnobody:masterfrom
mathieucarbou:feat/faster-com
Sep 28, 2026
Merged

tbnobody merged 1 commit into
tbnobody:masterfrom
mathieucarbou:feat/faster-com

Conversation

@mathieucarbou

@mathieucarbou mathieucarbou commented Sep 18, 2026 •

Copy link
Copy Markdown
Contributor

Problem

A radio transaction is currently only evaluated once its per-command RX
timeout expires, even when the inverter has already answered completely.
This is most noticeable for device-control commands (power limit,
power on/off), which use a 2000ms timeout: an acknowledgement typically
arrives within ~100ms, but the radio stays busy for the remaining ~1900ms
before the next queued command can be sent.

This makes OpenDTU comparatively slow for use cases that repeatedly send
power limit updates (e.g. dynamic/zero-export power control from an external
regulator such as Home Assistant or OpenDTU-on-Battery), since each update
costs a full timeout instead of the actual round-trip time.

Change

A transaction is now finalized as soon as all of its expected fragments have
been received, instead of waiting for the timeout in every case:

  • The last fragment of a response carries the 0x80 flag (already tracked in
    _rxFragmentMaxPacketId). Once that flag has been seen and every fragment
    up to it is present, completion is mathematically certain.
  • This is exposed as a new side-effect-free
    InverterAbstract::isTransactionComplete(). Unlike verifyAllFragments(),
    it does not touch the retransmit counters, so it can be checked on every
    loop iteration without affecting statistics or retry logic.
  • The radio's own RX fragment buffer must be fully drained
    (isRxBufferEmpty(), implemented per radio) before finalizing, so a
    fragment belonging to the current response can never be misattributed to
    the next transaction.
  • The existing RX timeout is kept unchanged as a fallback for incomplete or
    missing responses, so slow inverters, retransmissions and error handling
    behave exactly as before.

Single-frame device-control acknowledgements (power limit, power on/off)
qualify for early exit naturally, since their response is a single 0x81
frame. This reduces the effective cost of a power limit command from the
full 2000ms timeout down to the actual round-trip time (typically
~100-150ms).

ChannelChangeCommand is unaffected: it is fire-and-forget by design (no
response is ever expected), so isTransactionComplete() never returns true
for it and it keeps finalizing via its existing 10ms timeout.

Both changes make OpenDTU suitable for fast zero-export regulation loops
(e.g. Home Assistant reading a grid meter and publishing limit setpoints via
MQTT): a limit command now completes in its actual round-trip time
(~100-150ms) instead of the full 2000ms timeout, and it is sent before any
pending read requests.

This set of changes makes OpenDTU as fast as Ahoy for power control (limits).

This PR is based on #3226 and includes its commit.

Compatibility

  • No change to the CMT2300A/NRF24 drivers or their RX state machines.
  • No behavior change for incomplete, missing, or slow responses.
  • No change to command ordering, retry counts, or statistics semantics.

Impact

Power limit command: full 2000ms timeout → actual round-trip (~100-150ms).
Regulation cycle across 8 HMS inverters: ~16s → ~1s.

Testing

Tested at home on my 8 HMS-1000.

  • Before: the control loop was taking about 16 seconds to complete and the queue was always full of both commands and read requests
  • After: the control loop is fast: I can regulate 8 HMS in less than 2 seconds. The queue execution is faster so items are dequeues also faster.

As a consequence:

  • all the power control commands take less than 2 sec to execute
  • all the readings are fast
  • I can safely decrease the poll interval to 2 seconds to ensure faster reads and in any case, power control commands will be executed with a higher priority.
image

Some logs showing the changes

opendtu-log-2026-09-18_16-53-27.txt

@mathieucarbou

Copy link
Copy Markdown
Contributor Author

@tbnobody @schlimmchen FYI.

I know several people using OpenDTU for power limit control through Home Assistant.
Some have switched to Ahoy because of this issue. OpenDTU is really slow to regulate power when we need zero injection.

I've read the github history, why these timeouts were set high. No objection to that.
But if we receive an early ack, why still waiting.

I hope this PR will make in. That's a very good improvements in OpenDTU reactivity!

Note: a good thing of this PR is that MQTT validation could be dropped to 1 or 2 seconds in order for Home Assistant to get the feedback about the invert stats updates faster also.

@mathieucarbou
mathieucarbou force-pushed the feat/faster-com branch 4 times, most recently from 6c045a0 to 11aa4a6 Compare September 18, 2026 20:44
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 18, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 18, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 18, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 18, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
@mathieucarbou
mathieucarbou marked this pull request as draft September 19, 2026 09:18
@mathieucarbou

Copy link
Copy Markdown
Contributor Author

converted to draft - I saw this morning that all inverters were unreachable in OpenDTU. Checking what could cause that.

mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
@mathieucarbou mathieucarbou changed the title feat(hoymiles): priority-aware command queue and early RX exit for faster inverter control feat(hoymiles): early RX exit for faster inverter control Sep 19, 2026
@mathieucarbou
mathieucarbou marked this pull request as ready for review September 19, 2026 13:38
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
@mathieucarbou

Copy link
Copy Markdown
Contributor Author

I completed some testing thanks to PR #3227.

Regulation before this fix:

Capture d’écran 2026-09-19 à 15 43 59
  • DTU poll interval : 5 sec
  • Regulation each 30 sec

With 8 inverters this is not possible top improve more.

After this fix:

Capture d’écran 2026-09-19 à 16 17 16 image image

Queue is drained quickly and power control are sent within 2 sec.

mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 19, 2026
Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from Shelly Local Network Messaging.

Shelly LNM sends grid measurements through UDP multicast, avoiding
periodic HTTP polling. OpenDTU listens with WiFiUDP and processes
incoming datagrams from the scheduler without blocking inverter
communication or introducing additional request/response traffic.

The module provides:

- Enable/disable configuration
- Grid power setpoint
- Minimum production power
- Configurable regulation interval
- Shelly LNM multicast address and port
- Balanced power-limit distribution across inverters
- Handling for temporarily unreachable inverters
- Web API endpoints
- Home Assistant MQTT switch, setpoint, and status entities
- Zero-Export settings page in the web interface

The default regulation interval is 30 seconds. This allows HMS
inverters approximately 1-2 seconds to apply a new power limit and
gives Shelly LNM time to measure and propagate the updated grid value.

Once PR tbnobody#3225 is merged, communication will become immediate and up
to 10 inverters can be updated within approximately 2 seconds. The
regulation interval can then safely be reduced to the 5-second minimum.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 20, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the scheduler
  without blocking inverter communication. The wire protocol is the binary
  "SL" header followed by a JSON payload (em1:0 / em:0 / etc.).

- MQTT: any power meter publishing a plain numeric value or a JSON object
  with a power field (act_power / total_act_power, Shelly EM / 3EM style)
  can be used by subscribing to a configurable "Grid Power Topic" on the
  existing OpenDTU MQTT client. Retained messages are ignored so stale
  retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface,
making it straightforward to add more sources later.

The regulation loop reads the freshest grid power from the active source
(with an implementation-specific freshness timeout) and distributes the
needed correction proportionally to the inverters' rated power, never
going below a configurable minimal production (default: 100 W per
inverter). The tracked state is the set of limits the controller has
requested, not the values read back from the inverters.

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent, retried
  until all inverters have been positively released.
- On DTU restart with Zero-Export disabled, a release is scheduled so
  limits left by a previous run are not retained on the inverters.
- On DTU restart with Zero-Export enabled, each inverter starts at a
  100 W power floor so that the regulation does not guess a stale value.
- A keep-alive resend prevents the inverters' own non-persistent-limit
  timeout from silently reverting them to full power.
- If no fresh grid value is available, no RF traffic is generated.

The default regulation interval is 30 seconds. This allows HMS inverters
approximately 1-2 seconds to apply a new power limit and gives Shelly
LNM time to measure and propagate the updated grid value. Once PR tbnobody#3225
is merged, communication will become immediate and up to 10 inverters
can be updated within approximately 2 seconds, which would allow
reducing the regulation interval to the 5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power
- Regulation interval
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group and port
- MQTT grid power topic
- Live status (grid power, currently applied production limit) with
  a 5-second refresh

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch, a setpoint number, a grid power sensor and a
production-limit sensor; the switch and setpoint can be changed from
Home Assistant.

Closes: #<issue>
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 20, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits
based on grid power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the scheduler
  without blocking inverter communication. The wire protocol is the binary
  "SL" header followed by a JSON payload (em1:0 / em:0 / etc.).

- MQTT: any power meter publishing a plain numeric value or a JSON object
  with a power field (act_power / total_act_power, Shelly EM / 3EM style)
  can be used by subscribing to a configurable "Grid Power Topic" on the
  existing OpenDTU MQTT client. Retained messages are ignored so stale
  retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface,
making it straightforward to add more sources later.

The regulation loop reads the freshest grid power from the active source
(with an implementation-specific freshness timeout) and distributes the
needed correction proportionally to the inverters' rated power, never
going below a configurable minimal production (default: 100 W per
inverter). The tracked state is the set of limits the controller has
requested, not the values read back from the inverters.

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent, retried
  until all inverters have been positively released.
- On DTU restart with Zero-Export disabled, a release is scheduled so
  limits left by a previous run are not retained on the inverters.
- On DTU restart with Zero-Export enabled, each inverter starts at a
  100 W power floor so that the regulation does not guess a stale value.
- A keep-alive resend prevents the inverters' own non-persistent-limit
  timeout from silently reverting them to full power.
- If no fresh grid value is available, no RF traffic is generated.

The default regulation interval is 30 seconds. This allows HMS inverters
approximately 1-2 seconds to apply a new power limit and gives Shelly
LNM time to measure and propagate the updated grid value. Once PR tbnobody#3225
is merged, communication will become immediate and up to 10 inverters
can be updated within approximately 2 seconds, which would allow
reducing the regulation interval to the 5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power
- Regulation interval
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group and port
- MQTT grid power topic
- Live status (grid power, currently applied production limit) with
  a 5-second refresh

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch, a setpoint number, a grid power sensor and a
production-limit sensor; the switch and setpoint can be changed from
Home Assistant.

Closes: #<issue>
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 22, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 22, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 22, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 22, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
@tbnobody

Copy link
Copy Markdown
Owner

I already merged #3166 which also introduced commands which don't end up with 0x80. Maybe we need a exception in this program flow as well.

mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
@mathieucarbou
mathieucarbou marked this pull request as ready for review September 23, 2026 11:00
@mathieucarbou

mathieucarbou commented Sep 23, 2026 •

Copy link
Copy Markdown
Contributor Author

I already merged #3166 which also introduced commands which don't end up with 0x80. Maybe we need a exception in this program flow as well.

FYI 3 people I know of are testing this change since 3 days so far no issue :-)

For the commands which don't end up with 0x80, if you know the end you can add, otherwise the default timeout in place will be used to determine the end.

mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
@tbnobody

tbnobody commented Sep 23, 2026 •

Copy link
Copy Markdown
Owner

Yes, but early exit will not work for responses without '0x80' . Question is if this has any negative side effects when such responses are received. Without thinking deep into it, I would assume that the timeout will still be triggered. (Which is also Ok because the mentioned command is only executed once)

@mathieucarbou

mathieucarbou commented Sep 23, 2026 •

Copy link
Copy Markdown
Contributor Author

Yes, but early exit will not work for responses without '0x80' . Question is if this has any negative side effects when such responses are received. Without thinking deep into it, I would assume that the timeout will still be triggered. (Which is also Ok because the mentioned command is only executed once)

Yes that is true.

But this PR does not modify the existing behaviour. It just allows to not wait until the timeout finishes when we know com is finished. Some inverters do not answer with 0x80 and that's why for them the code will have to wait until the timeout ends like now. There is no change for them.

So instead of slowing down everybody, then, at least, for inverters that answer correctly, an early exit is proposed.

This is useless to continue to wait when we know the inverter has answered right ?

Especially for a Zero-Export feature, taking 2 sec per request to apply a limit is huge and inefficient: 10 inverters make up for 20 seconds to apply a new power limit, when they can all be applied within 2 seconds if we exit early when we can.

@tbnobody

Copy link
Copy Markdown
Owner

Just read the code again and merged it. Will be included in next release.

@SW-Niko

SW-Niko commented Sep 23, 2026

Copy link
Copy Markdown
Contributor

Hello @mathieucarbou , @tbnobody ,
In general, I really like the idea of ​​speeding up the regulation.
However, I fear that by doing so, we are opening the door to problems associated with control loops.

Let me explain why.

Some commands, such as the "power limit command" have not yet been completed by the time we receive the response from the inverter. It takes about 1s, before the new limit is settled on the AC output of the inverter. Right now we can trust the timing of the "power limit command". Once the command is complete, we know we have the correct AC power.

And now, we transfer the time behavior of the control loop more or less to the external system and leave the correct timing to the external programmer. And if we issue commands too quickly, we encounter control problems such as overshoot, undershoot, and oscillation.

Don't get me wrong: I am prepared to deal with the new timing characteristics and possess knowledge of control loops.
Furthermore, we would force forks of the repository to adopt the new timing behavior immediately.

Maybe we must mark this as a "major change" 🤔

@mathieucarbou

mathieucarbou commented Sep 23, 2026 •

Copy link
Copy Markdown
Contributor Author

Hello @mathieucarbou , @tbnobody , In general, I really like the idea of ​​speeding up the regulation. However, I fear that by doing so, we are opening the door to problems associated with control loops.

Let me explain why.

Some commands, such as the "power limit command" have not yet been completed by the time we receive the response from the inverter. It takes about 1s, before the new limit is settled on the AC output of the inverter. Right now we can trust the timing of the "power limit command". Once the command is complete, we know we have the correct AC power.

And now, we transfer the time behavior of the control loop more or less to the external system and leave the correct timing to the external programmer. And if we issue commands too quickly, we encounter control problems such as overshoot, undershoot, and oscillation.

Don't get me wrong: I am prepared to deal with the new timing characteristics and possess knowledge of control loops. Furthermore, we would force forks of the repository to adopt the new timing behavior immediately.

Maybe we must mark this as a "major change" 🤔

Keep as-is would work if we could sent all power limit commands concurrently: when the control loop runs, if it has to send 10 commands concurrently and wait 2 sec for a timeout, that's fine. That' 2 sec max.

But the reality is that commands are sent in sequence so by the time the last command will be sent, the other ones will be applied.

So we only need to account for 2 second in the control loop AFTER the last command was sent. An easy way is to prevent the regulation loop to be too short.

For example in my implementation I prevent the user from setting it lower than 5 seconds, which is enough to let room for the power change to be applied.

image

Also, do not forget that what is driving a control loop is mostly the measurements and their pace. So if you have a control loop shorter than the interval at which the measurements are coming, you can apply a sort of source-adaptive correction based on the intervals.

So I think that's totally fine.

What is not acceptable is the current behavior: commands are sent in sequence and waiting for a timeout of 2 sec for a command to be applied, when having 10 inverters make up for 20 seconds, so 22 seconds in total to have a power control applied when all can be done in 2 seconds! That was driving me crazy lol! No wonder why I know some people switched to Ahoy who does not wait for this timeout value but early exit instead.

mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 23, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 24, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
mathieucarbou added a commit to mathieucarbou/tbnobody-OpenDTU that referenced this pull request Sep 24, 2026
…d sources

Add a Zero-Export module that regulates Hoymiles inverter power limits so
that the grid power stays around a configurable setpoint (default: 0 W,
i.e. neither export to nor import from the grid), based on the grid
power received from a configurable grid source.

Two sources are currently available:

- Shelly LNM (Local Network Messaging): Shelly meters stream LNM status
  messages through UDP multicast, avoiding periodic HTTP polling. OpenDTU
  listens with WiFiUDP and processes incoming datagrams from the
  scheduler without blocking inverter communication. The wire format is
  a 12-byte binary header starting with the "SL" magic followed by a
  JSON payload (em1:0 / em:0 / etc.) whose act_power field carries the
  grid power.

- MQTT: any power meter publishing a plain numeric value or a JSON
  object with an act_power / total_act_power field (Shelly EM / 3EM
  style) can be used by subscribing to a configurable "Grid Power Topic"
  on the existing OpenDTU MQTT client. Retained messages are ignored so
  stale retained values never drive the regulation.

Grid sources are modelled as a small ZeroExportGridSource interface that
tracks measurement freshness, estimates the source update period as an
EWMA of the intervals between accepted samples, and enforces a
per-source fail-safe timeout. Adding a new source means implementing
the interface and adding a switch case.

The regulation loop reads the grid power from the active source and
distributes the needed correction proportionally to the inverters'
rated power, never commanding an inverter below a configurable minimal
production (default: 40 W per inverter). Inverters that are temporarily
unreachable keep their last commanded limit while the others
compensate. Upward corrections are damped for slow sources, using the
measured source period plus the estimated inverter response latency, to
avoid overshoot; downward corrections remain immediate to reduce
export. The tracked state is the set of limits this controller has
requested, not the values read back from the inverters (the one-time
startup adoption below is the only exception).

Safety behavior:

- Limits are only ever sent to reachable, command-enabled inverters.
- On disable, a RelativNonPersistent 100 % release is sent and retried
  each regulation tick until every command-enabled inverter has
  received it.
- After a DTU restart, limits left by a previous session are reverted
  by the inverters' own non-persistent-limit timeout; nothing is
  commanded until regulation is established. On startup each inverter
  adopts the limit currently active in the inverter once it becomes
  known through the regular SystemConfigPara poll, instead of guessing
  one, so a producing inverter is never yanked to another value.
  Re-enabling after a release starts at nominal power.
- When a grid measurement existed but has expired (measurement
  outage), a minimum-production fail-safe is commanded once per
  inverter and retried until it could be sent. It is deliberately not
  kept alive: if the inverter's own non-persistent-limit timeout
  reverts it to full power, the regulation loop readjusts as soon as
  fresh grid values arrive again.
- A source that has not delivered a single value yet (module just
  enabled, source just switched, network just reconnected) is a
  startup condition, not an outage: no RF traffic is generated and the
  inverters' limits are left untouched.
- Requested limits are capped above the currently measured production
  (with headroom), so they cannot drift far above what the inverters
  actually produce. The cap's base never drops below the enforced
  per-inverter floor sum, so a low-light start can always ramp up
  again.

The default regulation interval is 30 seconds (allowed range: 5-3600
seconds). With the current radio layer, each command occupies the
radio for its full RX timeout and the command queue also carries the
regular poll requests, so a 30 s interval leaves room for a full poll
cycle and for the grid source to measure the effect of a correction.
Once tbnobody#3225 ("feat(hoymiles): early RX exit for faster
inverter control") is merged, a limit command completes in its actual
round-trip time (~100-150 ms instead of the full 2000 ms timeout) and a
regulation cycle across 8 HMS inverters takes about 2 seconds instead
of ~16, which would allow reducing the regulation interval to the
5-second minimum.

The settings page exposes:

- Enable/disable switch
- Grid power setpoint
- Minimum production power per inverter (minimum 40 W)
- Regulation interval (5-3600 seconds)
- Grid source dropdown (Shelly LNM / MQTT)
- Shelly LNM multicast group, port and fail-safe timeout
  (defaults: 239.255.55.55:5555, 10 s)
- MQTT grid power topic and fail-safe timeout (default: 30 s)
- Live status with a 5-second refresh: grid power, measured grid
  update interval, and the currently applied production limit

The status API additionally reports per-inverter state (commanded
limit, pending startup / release / fail-safe flags, reachability,
command enablement).

Zero-Export state is published under dtu/zeroexport/status (enabled,
setpoint, production_limit, grid_update_period), and the module can be
controlled through dtu/zeroexport/cmd (enabled, setpoint). Changes
received through MQTT are applied live without persisting the
configuration to avoid flash wear.

Home Assistant integration (when MQTT auto-discovery is enabled)
publishes a switch (enabled), a setpoint number, a production-limit
sensor and a grid-update-interval diagnostic sensor; the switch and
the setpoint can be changed from Home Assistant.
@github-actions

Copy link
Copy Markdown

This pull request has been automatically locked since there has not been any recent activity after it was closed. Please open a new discussion or issue for related concerns.

Sign up for free to subscribe to this conversation on GitHub. Already have an account? Sign in.