MedQ-Deg: A Multidimensional Benchmark for Evaluating MLLMs Across Medical Image Quality Degradations
ECCV 2026 · Main Conference
-
[2026.09] MedQ-Deg published in Computer Vision – ECCV 2026, Part IX, pp. 246–264.
-
[2025.10] VLMEvalKit integration now supported!
-
[2025.10] MedQ-DEG-Bench dataset publicly released on Hugging Face
MedQ-Deg (released as MedQ-DEG-Bench) evaluates medical VLM robustness to image degradation and confidence calibration under degraded conditions. It contains 24,894 question-answer pairs across 7 imaging modalities, 18 degradation types, and 30 fine-grained clinical capabilities, with multi-severity evaluation.
Beyond accuracy, the benchmark uses Calibration Shift to quantify the gap between model confidence and actual performance. Evaluation of 40 MLLMs shows that models can retain inappropriately high confidence even as accuracy declines under severe image degradation.
- Systematic Degradation Simulation: 18 clinically-relevant degradation types across 7 medical imaging modalities
- Multi-Severity Evaluation: Each degradation applied at mild and severe levels to quantify robustness gradients
- Large-Scale Benchmark: 24,894 question-answer pairs covering degraded and clean reference images
- Clinical Capability Coverage: 30 fine-grained clinical capabilities
- Confidence Calibration Analysis: Calibration Shift measures the gap between model confidence and actual performance under degradation
- Multi-Source Aggregation: Samples sourced from 3 established medical VQA datasets
- Plug-and-Play Evaluation: Integrated with VLMEvalKit for seamless model evaluation
Key findings from MedQ-Deg. The benchmark uncovers three critical phenomena in medical VLM robustness: (i) a Calibration Shift — models sustain high confidence even as accuracy collapses under degradation, posing a silent safety risk in clinical deployment; (ii) a Cliff Effect — accuracy degradation is nonlinear with severity, with catastrophic failure emerging at the severe level; and (iii) differential Skill-Specific Robustness — clinical reasoning remains relatively resilient while medical perception (e.g., anatomical recognition) degrades most severely. Among degradation categories, modality-specific artifacts are the most destructive, causing the largest average accuracy drops.
| Split | Samples | Description |
|---|---|---|
MedQDEGBench_simulate_dev |
10,392 | Degraded images - development set |
MedQDEGBench_simulate_test |
10,196 | Degraded images - test set |
MedQDEGBench_good_dev |
2,153 | Clean reference images - development set |
MedQDEGBench_good_test |
2,153 | Clean reference images - test set |
| Modality | Description |
|---|---|
| CT | Computed Tomography |
| MRI | Magnetic Resonance Imaging |
| X-ray | Radiography |
| Ultrasound | Ultrasonography |
| Endoscopy | Endoscopic Imaging |
| Dermoscopy | Dermatoscopic Imaging |
| Histopathology | Histological Imaging |
We simulate 18 clinically-relevant degradation types across 5 categories. Each degradation is applied at two severity levels: mild and severe.
Artifacts (7 types, modality-specific)
| Degradation | Modality | Description |
|---|---|---|
| Limited-angle reconstruction | CT | Under-complete angular sampling producing streak and shadow artifacts |
| Sparse-view reconstruction | CT | Sub-sampled sinogram measurements causing ring artifacts and resolution loss |
| Bias field artifact | MRI | Smooth, spatially varying intensity inhomogeneity mimicking B1 field non-uniformity |
| Undersampling artifact | MRI | Accelerated k-space acquisition causing aliasing and ghosting |
| Ghosting artifact | MRI | Periodic motion-induced Gibbs ringing along the phase-encode direction |
| Blood cell artifact | Histopathology | Erythrocyte-like circular occlusions mimicking hemorrhage contamination |
| Dark spot artifact | Histopathology | Irregularly shaped dark regions mimicking air bubbles or staining precipitates |
Motion Interference (2 types, general)
| Degradation | Description |
|---|---|
| Object rotation | In-plane affine rotation simulating patient repositioning or gantry misalignment |
| Object movement | Random in-plane translation simulating patient displacement |
Intensity Jitter (3 types, general)
| Degradation | Description |
|---|---|
| Brightness adjustment | Uniform pixel intensity shift simulating over- or under-exposure |
| Exposure variation | Non-linear gamma correction mimicking sensor gain variations |
| Contrast reduction | Dynamic range compression simulating suboptimal window/level settings |
Noise (2 types)
| Degradation | Modality | Description |
|---|---|---|
| Gaussian noise | General | Zero-mean isotropic Gaussian noise modeling thermal detector noise |
| Low-dose noise | CT | Poisson noise model applied to sinogram domain simulating dose-reduced acquisition |
Resolution & Blur (4 types)
| Degradation | Modality | Description |
|---|---|---|
| Low resolution | General | Downsample and upsample simulating reduced spatial resolution |
| Motion blur | General | Directional convolution kernel modeling camera or patient motion |
| Gaussian blur | General | Isotropic Gaussian low-pass filter simulating optical defocus |
| Bubble | Histopathology | Semi-transparent circular regions mimicking air bubbles beneath coverslip |
The MedQ-DEG-Bench dataset is available on Hugging Face: jiyaoliufd/MedQ-DEG-Bench
MedQ-DEG-Bench is integrated with VLMEvalKit for standardized evaluation.
Please refer to the VLMEvalKit Quick Start Guide for installation instructions.
# Evaluate on degraded test set
python run.py --model grok-4 --data MedQDEGBench_simulate_test --api-nproc 32 --retry 3 --reuse
# Evaluate on clean reference test set
python run.py --model grok-4 --data MedQDEGBench_good_test --api-nproc 32 --retry 3 --reuse
# Evaluate on multiple splits
python run.py --model grok-4 --data MedQDEGBench_simulate_test MedQDEGBench_good_test --api-nproc 32 --retry 3 --reuseParameters:
--model: The model to evaluate (e.g.,grok-4,gpt-4o,qwen2.5-vl-72b)--data: Dataset split (see Dataset Composition)--api-nproc: Number of parallel API calls--retry: Number of retry attempts for failed API calls--reuse: Reuse existing results to avoid redundant API calls
The benchmark evaluates robustness through multi-dimensional accuracy analysis and examines confidence calibration:
- Overall Accuracy: Aggregate performance across all samples
- By Modality: Performance breakdown across 7 medical imaging modalities
- By Degradation Type: Accuracy for each of 18 degradation types
- By Severity Level: Comparison between mild, severe, and clean conditions
- By Source Dataset: Performance across different source medical VQA datasets
- By Capability: Performance across 30 fine-grained clinical capabilities
- Confidence Calibration: Calibration Shift quantifies the gap between perceived confidence and actual performance under degradation
- MedQ-Bench: Evaluating Medical Image Quality Assessment Abilities in MLLMs
- VLMEvalKit: Comprehensive evaluation toolkit for Vision-Language Models
If you use MedQ-DEG-Bench in your research, please cite our paper:
@inproceedings{liu2026medq,
title={MedQ-Deg: A Multidimensional Benchmark for Evaluating MLLMs Across Medical Image Quality Degradations},
author={Jiyao Liu and Junzhi Ning and Chenglong Ma and Wanying Qu and Jianghan Shen and Siqi Luo and Jinjie Wei and Jin Ye and Pengze Li and Tianbin Li and Jiashi Lin and Hongming Shan and Xinzhe Luo and Xiaohong Liu and Lihao Liu and Junjun He and Ningsheng Xu},
booktitle={Computer Vision -- ECCV 2026},
series={Lecture Notes in Computer Science},
volume={17009},
pages={246--264},
publisher={Springer Nature Switzerland},
year={2026},
doi={10.1007/978-3-032-37035-8_14},
url={https://doi.org/10.1007/978-3-032-37035-8_14}
}- Jiyao Liu: jiyaoliu.fudan@gmail.com
This project is licensed under the Apache License 2.0 - see the LICENSE file for details.
If MedQ-DEG-Bench helps your research, please consider giving us a star and citing our paper!


