Skip to content
liujiyaoFDUPublic

About

(ECCV 2026) Official repository for MedQ-Deg, a benchmark evaluating medical VLM robustness to image degradation. Features 24,894 QA pairs across 7 imaging modalities, 18 degradation types, and 30 clinical capabilities, with multi-severity evaluation and confidence calibration analysis.

Topics

Resources

Stars

26 stars

Watchers

0 watching

Forks

Latest commit

 

History

5 Commits

Folders and files

NameName
Last commit message
Last commit date
 
 
 
 
 
 

Repository files navigation

MedQ-Deg: A Multidimensional Benchmark for Evaluating MLLMs Across Medical Image Quality Degradations

ECCV 2026 · Main Conference

Typing SVG

ECCV 2026 arXiv License Python 3.8+ Dataset Project Page

Jiyao Liu1*, Junzhi Ning2*, Chenglong Ma1*, Wanying Qu1, Jianghan Shen2, Siqi Luo3, Jinjie Wei1, Jin Ye2, Pengze Li2, Tianbin Li2, Jiashi Lin2, Hongming Shan1, Xinzhe Luo4, Xiaohong Liu3, Lihao Liu2, Junjun He2†, and Ningsheng Xu1†
1Fudan University, 2Shanghai AI Lab, 3Shanghai Jiaotong University, 4Imperial College London
*Equal contribution. †Corresponding author.
MedQ-DEG-Bench Framework

News

Overview

MedQ-Deg (released as MedQ-DEG-Bench) evaluates medical VLM robustness to image degradation and confidence calibration under degraded conditions. It contains 24,894 question-answer pairs across 7 imaging modalities, 18 degradation types, and 30 fine-grained clinical capabilities, with multi-severity evaluation.

Beyond accuracy, the benchmark uses Calibration Shift to quantify the gap between model confidence and actual performance. Evaluation of 40 MLLMs shows that models can retain inappropriately high confidence even as accuracy declines under severe image degradation.

Key Features

  • Systematic Degradation Simulation: 18 clinically-relevant degradation types across 7 medical imaging modalities
  • Multi-Severity Evaluation: Each degradation applied at mild and severe levels to quantify robustness gradients
  • Large-Scale Benchmark: 24,894 question-answer pairs covering degraded and clean reference images
  • Clinical Capability Coverage: 30 fine-grained clinical capabilities
  • Confidence Calibration Analysis: Calibration Shift measures the gap between model confidence and actual performance under degradation
  • Multi-Source Aggregation: Samples sourced from 3 established medical VQA datasets
  • Plug-and-Play Evaluation: Integrated with VLMEvalKit for seamless model evaluation

Research Highlights

MedQ-Deg Research Highlights Poster

Key findings from MedQ-Deg. The benchmark uncovers three critical phenomena in medical VLM robustness: (i) a Calibration Shift — models sustain high confidence even as accuracy collapses under degradation, posing a silent safety risk in clinical deployment; (ii) a Cliff Effect — accuracy degradation is nonlinear with severity, with catastrophic failure emerging at the severe level; and (iii) differential Skill-Specific Robustness — clinical reasoning remains relatively resilient while medical perception (e.g., anatomical recognition) degrades most severely. Among degradation categories, modality-specific artifacts are the most destructive, causing the largest average accuracy drops.

Benchmark Architecture

Dataset Composition

Split Samples Description
MedQDEGBench_simulate_dev 10,392 Degraded images - development set
MedQDEGBench_simulate_test 10,196 Degraded images - test set
MedQDEGBench_good_dev 2,153 Clean reference images - development set
MedQDEGBench_good_test 2,153 Clean reference images - test set

Medical Imaging Modalities

Modality Description
CT Computed Tomography
MRI Magnetic Resonance Imaging
X-ray Radiography
Ultrasound Ultrasonography
Endoscopy Endoscopic Imaging
Dermoscopy Dermatoscopic Imaging
Histopathology Histological Imaging

Degradation Types

We simulate 18 clinically-relevant degradation types across 5 categories. Each degradation is applied at two severity levels: mild and severe.

Artifacts (7 types, modality-specific)

Degradation Modality Description
Limited-angle reconstruction CT Under-complete angular sampling producing streak and shadow artifacts
Sparse-view reconstruction CT Sub-sampled sinogram measurements causing ring artifacts and resolution loss
Bias field artifact MRI Smooth, spatially varying intensity inhomogeneity mimicking B1 field non-uniformity
Undersampling artifact MRI Accelerated k-space acquisition causing aliasing and ghosting
Ghosting artifact MRI Periodic motion-induced Gibbs ringing along the phase-encode direction
Blood cell artifact Histopathology Erythrocyte-like circular occlusions mimicking hemorrhage contamination
Dark spot artifact Histopathology Irregularly shaped dark regions mimicking air bubbles or staining precipitates

Motion Interference (2 types, general)

Degradation Description
Object rotation In-plane affine rotation simulating patient repositioning or gantry misalignment
Object movement Random in-plane translation simulating patient displacement

Intensity Jitter (3 types, general)

Degradation Description
Brightness adjustment Uniform pixel intensity shift simulating over- or under-exposure
Exposure variation Non-linear gamma correction mimicking sensor gain variations
Contrast reduction Dynamic range compression simulating suboptimal window/level settings

Noise (2 types)

Degradation Modality Description
Gaussian noise General Zero-mean isotropic Gaussian noise modeling thermal detector noise
Low-dose noise CT Poisson noise model applied to sinogram domain simulating dose-reduced acquisition

Resolution & Blur (4 types)

Degradation Modality Description
Low resolution General Downsample and upsample simulating reduced spatial resolution
Motion blur General Directional convolution kernel modeling camera or patient motion
Gaussian blur General Isotropic Gaussian low-pass filter simulating optical defocus
Bubble Histopathology Semi-transparent circular regions mimicking air bubbles beneath coverslip

Getting Started

Dataset Access

The MedQ-DEG-Bench dataset is available on Hugging Face: jiyaoliufd/MedQ-DEG-Bench

Evaluation with VLMEvalKit

MedQ-DEG-Bench is integrated with VLMEvalKit for standardized evaluation.

Installation

Please refer to the VLMEvalKit Quick Start Guide for installation instructions.

Usage

# Evaluate on degraded test set
python run.py --model grok-4 --data MedQDEGBench_simulate_test --api-nproc 32 --retry 3 --reuse

# Evaluate on clean reference test set
python run.py --model grok-4 --data MedQDEGBench_good_test --api-nproc 32 --retry 3 --reuse

# Evaluate on multiple splits
python run.py --model grok-4 --data MedQDEGBench_simulate_test MedQDEGBench_good_test --api-nproc 32 --retry 3 --reuse

Parameters:

  • --model: The model to evaluate (e.g., grok-4, gpt-4o, qwen2.5-vl-72b)
  • --data: Dataset split (see Dataset Composition)
  • --api-nproc: Number of parallel API calls
  • --retry: Number of retry attempts for failed API calls
  • --reuse: Reuse existing results to avoid redundant API calls

Evaluation Metrics

The benchmark evaluates robustness through multi-dimensional accuracy analysis and examines confidence calibration:

  • Overall Accuracy: Aggregate performance across all samples
  • By Modality: Performance breakdown across 7 medical imaging modalities
  • By Degradation Type: Accuracy for each of 18 degradation types
  • By Severity Level: Comparison between mild, severe, and clean conditions
  • By Source Dataset: Performance across different source medical VQA datasets
  • By Capability: Performance across 30 fine-grained clinical capabilities
  • Confidence Calibration: Calibration Shift quantifies the gap between perceived confidence and actual performance under degradation

Leaderboard

Leaderboard - Model performance comparison

Related Projects

  • MedQ-Bench: Evaluating Medical Image Quality Assessment Abilities in MLLMs
  • VLMEvalKit: Comprehensive evaluation toolkit for Vision-Language Models

Citation

If you use MedQ-DEG-Bench in your research, please cite our paper:

@inproceedings{liu2026medq,
  title={MedQ-Deg: A Multidimensional Benchmark for Evaluating MLLMs Across Medical Image Quality Degradations},
  author={Jiyao Liu and Junzhi Ning and Chenglong Ma and Wanying Qu and Jianghan Shen and Siqi Luo and Jinjie Wei and Jin Ye and Pengze Li and Tianbin Li and Jiashi Lin and Hongming Shan and Xinzhe Luo and Xiaohong Liu and Lihao Liu and Junjun He and Ningsheng Xu},
  booktitle={Computer Vision -- ECCV 2026},
  series={Lecture Notes in Computer Science},
  volume={17009},
  pages={246--264},
  publisher={Springer Nature Switzerland},
  year={2026},
  doi={10.1007/978-3-032-37035-8_14},
  url={https://doi.org/10.1007/978-3-032-37035-8_14}
}

Contact

License

This project is licensed under the Apache License 2.0 - see the LICENSE file for details.


If MedQ-DEG-Bench helps your research, please consider giving us a star and citing our paper!

About

(ECCV 2026) Official repository for MedQ-Deg, a benchmark evaluating medical VLM robustness to image degradation. Features 24,894 QA pairs across 7 imaging modalities, 18 degradation types, and 30 clinical capabilities, with multi-severity evaluation and confidence calibration analysis.

Topics

Resources

Stars

26 stars

Watchers

0 watching

Forks

Contributors