You signed in with another tab or window. Reload to refresh your session.You signed out in another tab or window. Reload to refresh your session.You switched accounts on another tab or window. Reload to refresh your session.Dismiss alert
{{ message }}
Repository navigation
Commit 4753b20
Browse filesBrowse the repository at this point in the historyBrowse files
Copy file name to clipboardExpand all lines: docs/debi/data-collection/1_session_prep.md
+26-28Lines changed: 26 additions & 28 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -1,12 +1,10 @@
1
-
## Session Preparation
2
-
3
-
### Documentation
1
+
## Documentation
4
2
5
3
-[ ] Prepare the informed consent form ([EN](../../assets/files/informed_consent/form-en.pdf)|[FR](../../assets/files/informed_consent/form-fr.pdf)|[DE](../../assets/files/informed_consent/form-de.pdf))
6
4
-[ ] Prepare an MRI safety screener ([EN](../../assets/files/mri_safety/safety_form-en.pdf)|[FR](../../assets/files/mri_safety/safety_form-fr.pdf))
7
5
-[ ] Prepare a pen and a [receipt form](../../assets/files/reimbursement.pdf) that the participant will sign when they are given the compensation
8
6
9
-
###Configure the IP address
7
+
## Configure the IP address
10
8
11
9
If you are connecting your PC to the eye tracker (ET) for the first time, you need to reconfigure the IP address.
@@ -95,7 +93,7 @@ Ensure the projector beam is directed into the scanner room.
95
93
96
94
!!! warning "The command elcl.exe will only work and start the software once the eye tracker device is connected to the ET PC. If you encounter any error messages, please ensure the eye tracker is connected to the PC inside the scanner room and try running the command again."
97
95
98
-
####Prepare the Eye Tracker device
96
+
### Prepare the Eye Tracker device
99
97
100
98
- All the lenses, mirrors, and other equipment are in the box in JB's office.
@@ -107,7 +105,7 @@ Ensure the projector beam is directed into the scanner room.
107
105
!!! tip "The default position of the screw for convenient focus is typically set to around `1`. However, the exact value can vary depending on the specific participant and setup for each time. It's recommended to start with the screw at value `1` and adjust from there for optimal focus during setup. If you're following a specific SOP, it might provide additional details for your equipment."
- Detach the standard mirror's frame from the head coil, if it is placed there.
113
111
- Take the infrared mirror out of the «fMRI usage» box. It should be always protected by a mask unless in use.
@@ -119,9 +117,9 @@ Ensure the projector beam is directed into the scanner room.
119
117
-**WITH THE GLOVES** proceed to extract the infra-red mirror from its box, being extremely careful. **YOU CAN ONLY TOUCH THE MIRROR WITH GLOVES**, because it cannot be cleaned up. Watch out for FINGERPRINTS and once taken out of the protection mask, IMMEDIATELY AND CAREFULLY ATTACH IT to the head coil.
@@ -130,7 +128,7 @@ Ensure the projector beam is directed into the scanner room.
130
128
131
129
!!! warning "No photo here due to magnetic field."
132
130
133
-
####Place the eye tracker and screen
131
+
### Place the eye tracker and screen
134
132
135
133
- Place the glass plate (stored in JB's office) on the scanner
136
134
- Position the ET on the glass plate according to the stickers on the plate.
@@ -152,24 +150,24 @@ Ensure the projector beam is directed into the scanner room.
152
150
ping 100.1.1.1
153
151
```
154
152
155
-
#### Place the participant
153
+
### Place the participant
156
154
157
-
##### Place the subject on the bed
155
+
#### Place the subject on the bed
158
156
159
157
- Provide the participant with a blanket, ear plugs and sand bags.
160
158
- Adjust the head coil and the mirror. If necessary, apply some pads to adjust the participant's head position to ensure the forehead tightly positioned against the head coil.
161
159
- Ensure the participant does not cross the legs.
162
160
- Provide the participant with the emergency button and explain that it can be pressed it in case of an emergency.
163
161
164
-
##### Adjust the scanner before send the subject inside
162
+
#### Adjust the scanner before send the subject inside
165
163
166
164
- Twist the knob to adjust the height of the bed and wait for it to stop.
167
165
- Gently move the participant with the manual controls. Stop when the head is under the head-localizer. Instruct the participant to close the eyes.
168
166
- Turn on the red light to localize the head. Put one hand on the head coil, then turn the knob left or right to align the red light with the mark on the head coil. Once aligned, turn off the red light and instruct the participant to open the eyes.
169
167
- Turn off the ventilation and set the scanner light to the minimum level.
170
168
- Send the participant into the scanner, then proceed to the console at the back of scanner.
171
169
172
-
##### Adjust the lens of eye tracker
170
+
#### Adjust the lens of eye tracker
173
171
174
172
- Point the lens of eye tracker towards the participant's right eye.
175
173
- The default position of the screw on the lens can be set to around 1 for convenient adjustment.
@@ -178,17 +176,17 @@ Ensure the projector beam is directed into the scanner room.
Inform the participant that you are leaving the room and will shortly come back for a final preparation.
186
184
187
-
#### Open psychopy in the psychopy laptop
185
+
### Open psychopy in the psychopy laptop
188
186
189
187
If you are connecting the eye tracker to the experimental laptop for the first time, you will need to configure it (see Section 0).
190
188
191
-
#### Run the experiment on psychopy
189
+
### Run the experiment on psychopy
192
190
193
191
Click the `Run Experiment` button, or run the experiment from the terminal by typing:
194
192
`python experiment.py`. All the experiments must have a calibration and validation phase before the experiment itself (they come with the software).
@@ -204,7 +202,7 @@ Click the `Run Experiment` button, or run the experiment from the terminal by ty
204
202
205
203
!!! important "For every new visual stimulation, even on the same subject, there must be new calibration and validation phases to ensure a proper generated EDF"
206
204
207
-
#### Run the calibration
205
+
### Run the calibration
208
206
209
207
Once the stimulation begins, follow the messages on the screen to run the calibration, make sure the following options are selected correctly
210
208
@@ -214,24 +212,24 @@ Once the stimulation begins, follow the messages on the screen to run the calibr
214
212
- Pupil Tracking: `Ellipse`
215
213
- Camera Position: `Right`
216
214
217
-
#### Apply threshold to find the pupil
215
+
### Apply threshold to find the pupil
218
216
219
217
- On the ET PC, click `Apply Threshold` (top left corner, as shown in the figure below). Ensure that the pupil is detected and that you see the blue cross on the eye. If you encounter issues, check the lighting inside the scanner (ensure it's not too bright or too dim) and verify the participant's position inside the coil. Once the calibration starts, accept the calibration points when they turn green by clicking `Accept Fixation` (the first click is always manual, the following ones are automatic or manual).
220
218
- If the calibration was successful, you will see the sentence `calibration successful` at the bottom in green. Check the stability of the accepted points and overall score of the calibration.
221
219
!!!tip "If the calibration points form a cross, it is a perfect calibration."
!!! tip "What you should see in an ideal situation is: the reference dot on the center of the screen and another dot that corresponds to the pupil calibration. The calibration dot is more or less stable moving a little around the reference dot."
227
225
!!! warning "If the calibration dot is unstable and is moving around far from the reference dot, the experimenter should go back clicking the restart button, adjust the contrast and redo the calibration. Once the calibration dot is quite stable, proceed with the validation clicking the accept fixation."
#### Go into the scanner room and inform the participant
229
+
### Go into the scanner room and inform the participant
232
230
233
231
Inform the participant that you are leaving the room and will now close the door to start. Let them also know that you are going to communicate with them very shortly to check that communications through the speaker are functioning.
Copy file name to clipboardExpand all lines: docs/debi/data-collection/2_run_scanning_session.md
+10-12Lines changed: 10 additions & 12 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -1,32 +1,30 @@
1
-
### Running the scanning session
2
-
3
-
#### Prepare the visual stimulation experiment
1
+
## Prepare the visual stimulation experiment
4
2
5
3
!!!info "Click [here](https://github.com/Evelyn92/MREye_psychopy/blob/main/ver25/fixation_dots_T1weighted_250127_last_run.py) to check out the psychopy code for the [2.0 MR-Eye study](https://data.snf.ch/grants/grant/220433), and [here](https://github.com/MattechLab/MR-EyeTrack/blob/dev/visual_stimuli/fixed_dot-16_grid_T1w.py) for the [MR-Eye Track study](https://hee-projets.heig-vd.ch/en/projects/183/MREye-Track)"
6
4
7
5
- At the end of the ET calibration we are ready to continue with the experiment.
8
6
- Wait for the sentence regarding the initial description of the task: “In this task you will see...”
9
7
- Now, get ready to prepare the scanning sequence (next step).
10
8
11
-
####Prepare the scanning sequence
9
+
## Prepare the scanning sequence
12
10
13
-
#####Copy the Pulseq (.seq) files
11
+
### Copy the Pulseq (.seq) files
14
12
15
13
If you are using Pulseq to develop your own sequences, the first thing you'd need to do is to copy your .seq files into the corresponding Siemens folder for Pulseq, in C:\ProgramData\Siemens\Numaris\MriCustomer\CustomerSeq\pulseq, as shown in the picture below.
You can refer to [our Github repository](https://github.com/MattechLab/pulseq4mreye) to check more about code and documentation of the pulseq sequences we used for the protocol.
20
18
21
-
#####Add a new patient
19
+
### Add a new patient
22
20
23
21
First, register a new patient, completing the **last name**, the **name**, the **patient ID** (you can press the Tab bar and the field will be automatically filled by the current timestamp), **date of birth**, age (automatic after entering the date of birth), **sex**, **height** and **weight**. On the right of the UI, open the Program Selection window to choose your protocol. If you don't have one yet, it is recommended to create one, so every time you scan a new subject, you don't have to drag and drop all the sequences, they will already be there! Select "**Any Polarization**" as RF Transmit Mode. Select "**Brain**" as Body Part and Laterality. Select "**Head First Supine**" as Patient Orientation. You're good to go!
The protocol includes several sequences. In DEBI protocol's case, a head-scout, a high-resolution anatomical image (MP-RAGE), and other sequences depending on the project: T1w-LIBRE for MR-Eye Track and T1w-LIBRE, T1w-VIBE, T2w-LIBRE, and T2w-TSE for 2.0 MR-Eye.
28
26
29
-
#####Load the Pulseq (.seq) files
27
+
### Load the Pulseq (.seq) files
30
28
31
29
Once you have run the scout and the MP-RAGE, and you have positioned the FOV accordingly (check the video recording below), load the .seq file by going to Sequence > Special.
32
30
@@ -41,7 +39,7 @@ Once you have run the scout and the MP-RAGE, and you have positioned the FOV acc
Your browser does not support the video? Click [here](https://github.com/MattechLab/sops/blob/dev/docs/assets/debi_protocol/selected/scan_eva.mp4) to download it.
86
84
87
-
#####How to acquire prescans
85
+
### How to acquire prescans
88
86
89
87
You can refer to this link documentation of monalisa reconstruction where we explained with a video recording how to do acquire the prescans:
90
88
[Prescan Acquisition Guide](https://mattechlab.github.io/monalisa/2-6_prescan_acquisition.html). Remember to enable "Adjust with Body Coil" in System > Adjustments (only for prescans).
91
89
92
90
!!! warning "When copying parameters from one sequence to another (HC to BC), make sure that the correct coils are selected!! E.g. If you copied the parameters (Copy Parameters + Adjustment Volume) from HC to BC, the coils selected for the BC scan are the ones from the HC, so you would need to manually select Body in System > Coils"
93
91
94
-
####Session Completed
92
+
## Session Completed
95
93
96
94
- At the end of the stimulation, click “t” on the experimental laptop and click the round button on the SyncBox to stop the running session.
Copy file name to clipboardExpand all lines: docs/debi/data-collection/3_session_teardown.md
+8-10Lines changed: 8 additions & 10 deletions
Display the source diff
Display the rich diff
Original file line number
Diff line number
Diff line change
@@ -1,6 +1,4 @@
1
-
### Session Tear-Down
2
-
3
-
#### Showing the Participant Out
1
+
### Showing the Participant Out
4
2
5
3
- Enter the scanner room, and announce yourself to the participant saying that you will get out the participant in a few seconds.
6
4
- Extract the participant by pressing the extraction button and then gently rolling the central knob. Alternatively, you can just press the Home button.
@@ -13,15 +11,15 @@
13
11
- Give the participant the corresponding compensation for the participation and transportation.
14
12
- Ask the participant to sign the receipt of the amount of the financial compensation.
15
13
16
-
####ET setting
14
+
### ET setting
17
15
18
16
- Place the half-circle screen back to the table behind the scanner.
19
17
- Unplug the two cables (signal and power) connected to the ET arm.
20
18
- Roll the two ET cables and put them in the cupboard inside the Scanning room.
21
19
- Remove the mirror frame from its rails mounted on the head coil and lay it on the bed.
22
20
- Put the gloves on and cover the infrared mirror with a mask for storage.
23
21
24
-
####Clearing up the Scanner
22
+
### Clearing up the Scanner
25
23
26
24
- Unplug the cable on the scanner from SyncBox and roll it back to the shelf.
27
25
- Remove used blankets and bed-sheets ONE-BY-ONE: extend them to let any forgotten items fall on the floor before you fold it; and dispose of them in the adequate bin (soiled linen bag if they are fabric and trash if they are disposable).
@@ -38,7 +36,7 @@
38
36
- Exit and close the external door.
39
37
!!! warning "Everything that is removed for the experiment needs to be put back in place at the end of the experiment, i.e., position of the bed, coil, emergency button, ears cover."
40
38
41
-
####Collect ET data
39
+
### Collect ET data
42
40
43
41
- Copy data from the subfolder of PsychoPy program into the hard drive.
44
42
!!! tip "The subfolder should include the files for one session with the formats like
0 commit comments