This document explains why the code is shaped the way it is. For how to extend it, see DEVELOPMENT.md.
┌──────────────────────────────────────────┐
│ ui/ pages, widgets, themes │ Qt lives only here
├──────────────────────────────────────────┤
│ services/ monitor, history, alerts, │ Qt for signals/timers
│ diagnostics, export │
├──────────────────────────────────────────┤
│ collectors/ one per domain │ no Qt
├──────────────────────────────────────────┤
│ models/ frozen snapshot dataclasses │ no Qt, no I/O
├──────────────────────────────────────────┤
│ core/ capabilities, DI, config, │ no Qt
│ units, ring buffers │
└──────────────────────────────────────────┘
Dependencies point downward only. The practical payoff: the entire data layer
runs under pytest with no display server, no event loop and no QApplication.
Over two-thirds of the test suite exercises real collectors against the real
machine in under eight seconds.
This is the single most consequential decision in the codebase.
On Linux, whether a metric exists depends on the kernel version, the distribution, the hardware and the permissions of the running user. RAPL power counters are root-only since CVE-2020-8694. SMART needs raw device access. A laptop GPU may have no controllable fan. Integrated graphics have no VRAM.
Three ways to handle that, two of them bad:
| Approach | Problem |
|---|---|
| Raise an exception | Every call site needs a try; one missing sensor breaks a page |
Return 0 or None |
The user cannot tell "idle" from "unmeasurable" |
Return Unavailable(reason, detail) |
Absence carries its explanation |
@dataclass(frozen=True, slots=True)
class Unavailable:
reason: Reason = Reason.PENDING
detail: str = ""
def __bool__(self) -> bool:
return FalseIt is falsy, so if value: reads naturally. It stringifies to a displayable
explanation. It has an actionable property distinguishing install this tool
from this hardware does not exist, which the Diagnostics page uses to produce
a list of things the user could actually fix.
Every formatter in core/units.py accepts it, so views format unconditionally:
tile.set_from(snapshot.package_power_w, watts)
# → "28.4 W", or an em dash whose tooltip reads
# "Insufficient permissions: energy_uj is root-only on this kernel"The marker survives JSON export as a structured object, so a script consuming the export can also tell absence from zero.
is_number() exists because isinstance(value, float) is a subtly wrong
availability test: sysfs and psutil both return plain integers for some
readings, and a float-only check silently classifies an integer temperature as
absent. That defect existed in this codebase and was caught by a unit test; the
predicate and its test now prevent its return.
core/capabilities.py probes for every optional feature at start-up and caches
the result behind functools.cached_property. Collectors consult the registry
instead of rediscovering the environment on every poll, and each absent
capability carries the reason that later becomes an Unavailable.
@cached_property
def rapl_power(self) -> Capability:
domains = sysfs.glob("class/powercap/intel-rapl:*/energy_uj")
if not domains:
return Capability("rapl_power", False, Reason.NO_DRIVER, ...)
if sysfs.read_int(domains[0]) is None:
return Capability("rapl_power", False, Reason.PERMISSION, ...)
return Capability("rapl_power", True)Note that it distinguishes absent from forbidden. The user can act on the second.
Ten collectors want different cadences, and their costs differ by two orders of
magnitude — /proc/stat takes 0.5 ms, the process table 60 ms, systemd 650 ms.
All of it must happen without the interface dropping a frame.
| Design | Why not |
|---|---|
| One thread per collector | Ten mostly-idle OS threads; fiddly shutdown |
| One shared worker thread | The 650 ms systemd poll stalls the 1 s CPU chart |
| Ticker + bounded thread pool | Chosen |
A single QTimer on the GUI thread fires every 200 ms, compares timestamps, and
dispatches due collectors to a four-thread QThreadPool. The ticker itself does
no work beyond arithmetic.
Guarantees:
- No overlapping runs. A collector still working when its slot arrives is skipped and its next attempt pushed out, so a chronically slow collector degrades its own frequency rather than saturating the pool.
- Results arrive on the GUI thread. Snapshots cross the boundary through a queued Qt signal connection; no view ever touches data a worker is mutating.
- Payloads are immutable. Snapshots are frozen dataclasses, so there is nothing to race on even if a consumer keeps a reference.
Measured on the development machine (6C/12T laptop, 370 processes):
GUI heartbeat target 50 ms → median 50.1 ms, p95 50.3 ms, max 51.2 ms
Beats exceeding 100 ms: 0 (measured across a 40-second run)
The first working version cost 21.5% of a core. Profiling found four causes, each fixed in a way worth recording:
| Problem | Cost | Fix |
|---|---|---|
psutil.sensors_temperatures() scans every hwmon chip; three collectors each called it |
9 ms × 3 | A shared provider with a 450 ms TTL, plus a targeted per-chip reader that caches resolved sysfs paths — 9 ms → 0.27 ms |
nvidia-smi cost scales with requested field count |
42 ms | Split the query: identity once per session, telemetry per sample — 25 ms |
The GPU process list needs a second nvidia-smi |
22 ms/sample | Refresh every fourth sample; the process set changes slowly |
powerprofilesctl is a Python D-Bus script |
93 ms/sample | Cache for 60 s — 1.9 ms |
psutil.net_connections(kind="unix") builds an object per socket to produce a count |
16 ms | Count lines in /proc/net/unix |
Result: 21.5% → ~9% of one core, with systemd additionally suspended
whenever its page is closed. The Diagnostics page shows the live per-collector
breakdown, so the application can be held to its own standard.
A separate incident is worth recording because it was not a micro-optimisation:
bluetoothctl devices, invoked non-interactively without a powered controller,
blocks waiting for input until killed — a four-second stall of a worker
thread. It was replaced by a sysfs read. The lesson generalises: every external
command runs under a hard timeout, and an interactive REPL is never a data
source.
Most interesting Linux metrics are monotonic counters. Converting them to rates
is where monitoring tools quietly go wrong, so RateTracker handles the three
failure modes explicitly:
- First sample — no previous value, so the rate is
0.0, not the absolute counter value (which would render as an enormous opening spike). - Counter reset — an interface goes down, a device is re-plugged, a 32-bit
counter wraps. A negative delta reports
0.0, never negative traffic. - Irregular intervals — rates divide by measured elapsed time, never the configured interval, so a late tick cannot inflate the figure.
forget(prefix) discards a departed device's counters, because otherwise a
replacement with the same kernel name would produce one enormous false spike
from the stale baseline.
Charts and history have different needs, so they get different storage.
In memory — a fixed-capacity collections.deque ring buffer per metric.
O(1) append, automatic eviction, bounded memory no matter how long the session
runs.
On disk — SQLite, written behind a flush timer. Samples accumulate in memory and are committed in one transaction every 15 seconds; a transaction per metric per second would mean thousands of fsyncs a minute.
The schema is deliberately narrow — (timestamp, metric, value) triples rather
than a column per metric. A wide table would need a migration every time a
metric is added and would be mostly NULL on a machine with no GPU or battery.
WAL journalling lets the interface read history while the writer appends.
Retention enforces both an age limit and a size ceiling, with a VACUUM after a
large prune because SQLite otherwise keeps the freed pages.
A naive "CPU > 90%" rule fires when you open a browser and trains the user to ignore alerts. Two mechanisms prevent that:
Sustain windows. A rule fires only once its condition has held continuously
for sustain_seconds. A momentary spike resets the timer without firing.
Hysteresis. Once firing, a rule clears only when the value retreats past the threshold by 3%. Without it a metric sitting exactly on the boundary would fire and clear on alternate samples.
Both are covered by tests driven from a controlled clock rather than real time.
Design tokens. Every colour, radius and spacing step is named once in
ui/themes/tokens.py. Widgets reference tokens, never literals, so a new theme
is a new Palette instance and the charts provably agree with the stylesheet.
Generated stylesheets. Qt Style Sheets have no variables, so the QSS is built from the active palette at run time.
Two Qt-specific traps are worth recording, because both produced visible bugs during development:
- A plain
QWidgetsubclass ignores a stylesheetbackgroundunlessWA_StyledBackgroundis set. The sidebar rendered light-on-light until this was applied — and again for the unnamed widget inside its scroll area. - pyqtgraph does not inherit the parent's stylesheet.
setBackground(None)leaves the default light grey, so a dark-theme card contains a glaring white plot. The surface colour must be passed explicitly.
Custom painting where it pays. Ring gauges, bar meters, the core heatmap and
the composition bar are painted with QPainter. A 128-thread core heatmap is
one paintEvent, not 128 stylesheet-evaluated child widgets.
Model/view for large tables. The process table refreshes several hundred
rows every 2.5 seconds. QTableWidget would destroy and recreate an item per
cell — tens of thousands of allocations per refresh, discarding the user's
selection and scroll position each time. A model emits dataChanged instead and
keeps both. Sorting uses a separate raw-value role, so a "Memory" column sorts
on an integer byte count while displaying 1.4 GiB.
Lazy pages with snapshot replay. Pages are built on first visit, so start-up only pays for what the user opens. Because a lazily-built page would otherwise miss every snapshot that arrived before it existed — up to 30 seconds of empty table for systemd — the window caches the latest snapshot per domain and replays it on first build.
app/bootstrap.py is the only module that knows how the object graph fits
together. Everything else receives collaborators through constructor parameters.
The container is 75 lines and provides exactly three things: lazy singletons,
one wiring location, and constructor injection for tests. It detects circular
dependencies and disposes services in reverse instantiation order.
Cross-domain enrichment is pushed, not pulled: the GPU snapshot's per-process VRAM figures are handed to the process collector by the bootstrap wiring, so the process collector keeps no dependency on the GPU layer and remains testable on a machine with no graphics adapter.
- Allow-listed actions. systemd verbs come from a frozen set; an arbitrary string can never reach the command line.
- Validated unit names. A strict pattern rejects anything containing shell metacharacters, option prefixes or path traversal. Nine adversarial inputs are covered by tests.
- No shell, ever. Every subprocess is invoked with an argument list.
- Hard timeouts. No external command can stall the pipeline.
- No password handling. Escalation is delegated to
pkexec, which presents the desktop's own dialog. - Credential masking. Process environment variables whose names suggest secrets are redacted before display — deliberately over-broad, because a monitoring UI gets screen-shared.
- Self-protection. The process collector refuses to signal PID 1 or its own process.